PA 1102 Black - Polyamide 11

EOSArticle Number: 9012-0100

Suitable for FORMIGA P 110 Velocis, EOS P 396, and EOS P 770

Comparable ductility as PA 1101 and strain at break, but in black for visible areas subject to wear.

Description

Parts made from the mass-dyed polyamide 11 powder have a uniform black color and are therefore particularly suitable for visible areas that are subject to abrasion or wear. In addition, they have comparable ductility and strain at break as PA 1101 and do not splinter even under the highest levels of mechanical stress. Compared to PA 12, they have higher temperature resistance and nearly constant mechanical properties over a wide temperature range. The material PA 1102 black is based on renewable resources (castor oil). 

Thermal properties
Melting temperature (20°C/min): 201°C

Physical properties
Density (lasersintered): 990 kg/m³

This material is ideally suited for producing functional elements that require high material strength (e.g. living hinges) and/or impact resistance. Therefore, components for which fragmentation is inadmissible (e.g. in the interior of vehicles) are among the typical fields of application.

The data corresponds to our knowledge and experience at the time of publication. They do not on their own represent a sufficient basis for any design, neither do they provide any agreement about or guarantee the specific properties of a product or part or the suitability of a product or part for a specific application. It is the responsibility of the producer or customer of a part to check its properties as well as its suitability for a particular purpose. This also applies regarding the consideration of possible intellectual property rights as well as laws and regulations. The data are subject to change without notice as part of EOS's continuous development and improvement processes. When using this product in or for medical devices as defined in directive 2007/47/EC (Medical Device(s)), you should be aware that this product has not been developed or tested for such use and that it is your sole responsibility to determine the suitability of this product for such use at your sole risk. To our knowledge, no clinical medical studies concerning the use of this product in any particular Medical Device have been performed, and approval from the European Directorate for the Quality of Medicines (“EDQM”) or other governmental authorities for use in Medical Devices has neither been sought nor received. Subject to your sole responsibility to determine suitability of the product for use in any Medical Product, the manufacturer of this product expressly advises not to consider its possible use for any Medical Product application other than body orthesis, orthopedic insole/arch-support, surgical guides and tools, therapy masks and dental models, and also expressly warns that, in any event, it should not be introduced into the human body for more than 30 days and should not replace any epithetical surface or the surface of the eye for more than 30 days. For more information, please contact your sales manager.

Safety Data Sheets can be found on myEOS

You may also like

Recently viewed